329 research outputs found

    Negative Wigner function at telecommunication wavelength from homodyne detection

    Full text link
    Quantum states of light having a Wigner function with negative values represent a key resource in quantum communication and quantum information processing. Here, we present the generation of such a state at the telecommunication wavelength of 1550nm. The state is generated by means of photon subtraction from a weakly squeezed vacuum state and is heralded by the `click' of a single photon counter. Balanced homodyne detection is applied to reconstruct the Wigner function, also yielding the state's photon number distribution. The heralding photons are frequency up-converted to 532nm to allow for the use of a room-temperature (silicon) avalanche photo diode. The Wigner function reads W(0,0)=-0.063 +/- 0.004 at the origin of phase space, which certifies negativity with more than 15 standard deviations

    Optical Absorption Measurements on Crystalline Silicon at 1550nm

    Full text link
    Crystalline silicon is currently being discussed as test-mass material for future generations of gravitational wave detectors that will operate at cryogenic temperatures. We present optical absorption measurements on a large-dimension sample of crystalline silicon at a wavelength of 1550nm at room temperature. The absorption was measured in a monolithic cavity setup using the photo-thermal self-phase modulation technique. The result for the absorption coefficient of this float-zone sample with a specific resistivity of 11kOhm cm was measured to be \alpha_A=(264 +/- 39)ppm/cm.Comment: 11 pages, 6 figures, 1 tabl

    Birefringence Measurements on Crystalline Silicon

    Get PDF
    Crystalline silicon has been proposed as a new test mass material in third generation gravitational wave detectors such as the Einstein Telescope (ET). Birefringence can reduce the interferometric contrast and can produce dynamical disturbances in interferometers. In this work we use the method of polarisation-dependent resonance frequency analysis of Fabry-Perot-cavities containing silicon as a birefringent medium. Our measurements show a birefringence of silicon along the (111) axis of the order of Δ n≈10−7\Delta\, n \approx 10^{-7} at a laser wavelength of 1550nm and room temperature. A model is presented that explains the results of different settings of our measurements as a superposition of elastic strains caused by external stresses in the sample and plastic strains possibly generated during the production process. An application of our theory on the proposed ET test mass geometry suggests no critical effect on birefringence due to elastic strains.Comment: 19 pages, 6 figures, 2 table

    Implementation of Quantum Key Distribution with Composable Security Against Coherent Attacks using Einstein-Podolsky-Rosen Entanglement

    Get PDF
    Secret communication over public channels is one of the central pillars of a modern information society. Using quantum key distribution (QKD) this is achieved without relying on the hardness of mathematical problems which might be compromised by improved algorithms or by future quantum computers. State-of-the-art QKD requires composable security against coherent attacks for a finite number of samples. Here, we present the first implementation of QKD satisfying this requirement and additionally achieving security which is independent of any possible flaws in the implementation of the receiver. By distributing strongly Einstein-Podolsky-Rosen entangled continuous variable (CV) light in a table-top arrangement, we generated secret keys using a highly efficient error reconciliation algorithm. Since CV encoding is compatible with conventional optical communication technology, we consider our work to be a major promotion for commercialized QKD providing composable security against the most general channel attacks.Comment: 7 pages, 3 figure

    In-situ cosmogenic <sup>36</sup>Cl denudation rates of carbonates in Guizhou karst area

    Get PDF
    This study quantifies surface denudation of carbonate rocks by the first application of in-situ cosmogenic &lt;sup&gt;36&lt;/sup&gt;Cl in China. Concentrations of natural Cl and in-situ cosmogenic &lt;sup&gt;36&lt;/sup&gt;Cl in bare carbonates from Guizhou karst areas were measured with isotope dilution by accelerator mass spectrometer. The Cl concentration varied from 16 to 206 ppm. The &lt;sup&gt;36&lt;/sup&gt;Cl concentrations were in range of (0.8–2.4)×106 atom g−1, resulting in total denudation rates of 20–50 mm ka−1 that averaged over a 104–105 a timescale. The &lt;sup&gt;36&lt;/sup&gt;Cl-denudation rates showed roughly a negative correlation with the local mean temperature. This preliminary observation may suggest the variations of proportions of chemical weathering and physical erosion in denudation process, depending upon local climatic conditions

    Diagnostic Specificity of Two Dengue Virus IgG ELISAs after Yellow Fever and Japanese Encephalitis Virus Vaccination

    Get PDF
    Dengue virus (DENV) antibody assays frequently cross-react with sera from individuals who have been infected with or vaccinated against related flaviviruses. The goal of this study was to determine the specificity of two DENV ELISAs with sera from individuals vaccinated against yellow fever virus (YFV) and Japanese encephalitis virus (JEV). The Panbio and the Novatec Dengue IgG ELISAs were tested with sera obtained 3–4 weeks or 0.5–6 years after YFV or JEV vaccination and the diagnostic specificity of the assays was determined. As controls, the sera were tested using DENV, YFV, JEV, Zika and West Nile virus neutralization assays. The diagnostic specificity of the Panbio and the Novatec ELISA with sera from YFV-vaccinated subjects was 98.2% and 88.2%, respectively. Cross-reactions were rare in the first 4 weeks despite high YFV-neutralizing antibody titers and were mostly found later. The specificity of the Panbio and Novatec assays with sera from JEV-vaccinated individuals was 100% and 92.9%. Cross-reactions occurred in the early time period after vaccination. The measurement values of the two ELISAs correlated strongly. Thus, the Panbio ELISA showed higher diagnostic specificity and may be suitable for seroprevalence studies in areas with high disease prevalence

    The Ratio of ADP- to TRAP-Induced Platelet Aggregation Quantifies P2Y(12)-Dependent Platelet Inhibition Independently of the Platelet Count

    Get PDF
    Objective This study aimed to assess the association of clinical factors with P2Y(12)-dependent platelet inhibition as monitored by the ratio of ADP-to TRAP-induced platelet aggregation and conventional ADP-induced aggregation, respectively. Background Controversial findings to identify and overcome high platelet reactivity (HPR) after coronary stent-implantation and to improve clinical outcome by tailored anti-platelet therapy exist. Monitoring anti-platelet therapy ex vivo underlies several confounding parameters causing that ex vivo platelet aggregation might not reflect in vivo platelet inhibition. Methods In a single centre observational study, multiple electrode aggregometry was performed in whole blood of patients after recent coronary stent-implantation. Relative ADP-induced aggregation (r-ADP-agg) was defined as the ratio of ADP-to TRAP-induced aggregation reflecting the individual degree of P2Y(12)-mediated platelet reactivity. Results Platelet aggregation was assessed in 359 patients. Means (+/- SD) of TRAP-, ADP-induced aggregation and r-ADP-agg were 794 +/- 239 AU* min, 297 +/- 153 AU* min and 37 +/- 14%, respectively. While ADP-and TRAP-induced platelet aggregation correlated significantly with platelet count (ADP: r = 0.302;p< 0.001;TRAP: r = 0.509 p< 0.001), r-ADP-agg values did not (r = -0.003;p = 0.960). These findings were unaltered in multivariate analyses adjusting for a range of factors potentially influencing platelet aggregation. The presence of an acute coronary syndrome and body weight were found to correlate with both ADP-induced platelet aggregation and r-ADP-agg. Conclusion The ratio of ADP-to TRAP-induced platelet aggregation quantifies P2Y(12)-dependent platelet inhibition independently of the platelet count in contrast to conventional ADP-induced aggregation. Furthermore, r-ADP-agg was associated with the presence of an acute coronary syndrome and body weight as well as ADP-induced aggregation. Thus, the r-ADP-agg is a more valid reflecting platelet aggregation and potentially prognosis after coronary stent-implantation in P2Y(12)-mediated HPR than conventional ADP-induced platelet aggregation
    • …
    corecore